Do more for less with the powerful, yet affordable Sun StorageTek 3320 SCSI array. This high-density, modular, enterprise-class array is designed for demanding workgroup and departmental environments. The adaptable and scalable Sun StorageTek 3320 SCSI array helps simplify storage planning and reduce costs; providing the flexibility to meet both current and future storage needs. Easy deployment and streamlined management mean less time spent configuring, reconfiguring, monitoring, and diagnosing your storage arrays.
|
- Up to 3.6 terabytes of capacity per tray
- Hardware or software based RAID
- 2U, 12 drive form factor
- Redundant components
|
 |
 |
- STANDARD INTERFACES :
- Host interface: 320MB SCSI LVD
- Drives
- 320MB SCSI 3.5 in. low profile
- Supported drives: 73GB 10K rpm; 73GB 15K rpm; 146GB 10K rpm, 146GB 15K rpm, 300GB 10K rpm
- Maximum number of host ports: Dual RAID controllers: 4x320MB SCSI host ports (no expansion); 2x2320MB SCSI host ports with expansion trays
- Maximum cable length: 12m
- CAPACITY :
- Total raw capacity
- 73GB 10K rpm and 15K rpm HDDs - 876GB per 2U tray; expandable to 2.6TB per RAID array
- 146GB 10K rpm HDDs - 1.72TB per 2U tray; expandable to 5.2TB per RAID array
- 300GB 10K rpm HDDs 3.60TB per 2U tray; expandable to 10.8TB per RAID array
- CONTROLLER CARD :
- RAID configurations:
- Per tray: JBOD/expansion (no controller); single RAID controller; dual (mirrored) RAID controllers
- RAID levels: 0, 1, 0+1, 1+0, 3, 5, 3+0, and 5+0
- Max. LUNS: Up to 1,024 per RAID array
- Max. local and/or global hot spares: Up to 20 (RAID set and disk quantity dependent) per RAID array
- Data Cache: 512MB per controller
- Cache battery backup: Up to 72 hours
- Cache write policy (user configurable): Write Back-default; Write Through-default for single controller or on battery/controller failure
- Included management software: Sun StorEdge Configuration Service software; Sun StorEdge Diagnostic Reporter software
- Supported Software (Optional):
- Sun StorEdge Enterprise Storage Manager software
- Sun StorEdge Traffic Manager software
- Sun Cluster 3 software
- VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorEdge Resource Management, Sun StorEdge Utilization, and Sun StorEdge Performance Suites
- SUPPORTED PLATFORMS :
- Servers
- All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers
- Supported HBAs
- Sun Solaris Operating Systems 8, 9, 10 (SPARC-based) - HBAs: SG-(X)PCI1SCSI-LP320; SG-XPCI2SCSI-LM320, (X)6758A; (X)2222A; (X)4422A; (X)1018A
- Sun Solaris x86 9, 10 - HBAs: X9265A/X9269A (Sun Fire V20z, V40z), SG-XPCI2SCSI-LM320; X5132A (Sun Fire V60, V65)
- Red Hat Linux, Enterprise Edition, 32b 64b; Novell SuSE Linux Enterprise server 8; Novell SuSE Linux 9 - HBAs: X5132A (Sun Fire V60, V65 servers); X9265A/X9269A (Sun Fire V20z and V40z servers); LSI Logic LSI2230-R; Adaptec 39160
- MS Windows NT EE 4.0/2000/2003 server/Novell NetWare 5.1, 6.0, 6.5 - HBAs: LSI Logic LSI2230-R; Adaptec 39160
- HP-UX 11.0 and 11i - HBA: HP A6829A
- IBM-AIX 4.3.3 and 5.1L (32 and 64 bit) - HBA: IBM SYM53C1010
- Operating System
- Sun Solaris Operating Environments 8, 9, 10, SPARC Platform Edition
- Solaris 10 operating system, x86 Platform Edition
- Red Hat Linux AS 3.0
- Microsoft Windows 2000 Advanced Server and Windows 2003 Server
- IBM AIX 5.1
- HP-UX 11i
- Novell Netware 5.1 and 6.5
- SUSE LINUX Enterprise Server 9.0, (32-bit and 64-bit)
- RELIABILITY, AVAILABILITY, SERVICEABILITY (RAS) :
- Hot-swap RAID controllers with battery-backed mirrored 512MB cache, (with dual RAID controllers)
- Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
- Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
- Hot-swap, redundant electrically-isolated redundant cooling fans
- Non-disruptive firmware upgrades (with dual RAID controllers via SSCS)
- ELECTRICAL REQUIREMENTS :
- Watts
- 420W each (Dual hot-swap redundant power supplies)
- Operating voltage
- 100 to 240 VAC, single phase
- AC Power Requirement: 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
- AC Current per input: 100 to 240 VAC, 50 to 60 Hz, 5.0-7.1A
- DC Voltage: -48 or -60 VDC, 18A
- DC power
- -36 to -75 VDC
- DC Current per input: -48 or -60 VDC, 18A
- ENVIRONMENT :
- Temperature
- Operating: 5 deg C to 40 deg C (41 deg F to 104 deg F)
- Nonoperating: -40 deg C to 65 deg C (-40 deg F to 149 deg F)
- Humidity
- Operating: 10 percent to 90 percent relative to 38 deg C
- Nonoperating: 0 percent to 90 percent relative to 27 deg C
- Altitude
- Operating: -30m to 3048m (-100 to 10,000 ft.)
- Nonoperating: -30m to 12,192m (-100 to 40,000 ft.)
- Shock
- Operating: 5.0 G, 11-ms, half-sine
- Nonoperating: 15.0 G, 11-ms, half-sine
- Vibration
- Operating: 0.2 G, 5-500 Hz, swept-sine
- Nonoperating: 1.0 G, 5-500 Hz, swept-sine
- Noise
- REGULATIONS: Meets or exceeds the following requirements: :
- Safety
- UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003
- Emissions
- VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark
- Harmonics
- IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001M
- Immunity
- NEBS
- Ruggedized: NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386
- DIMENSIONS AND WEIGHT :
- Dimensions (Height, Width, Depth): H: 8.8 cm (3.5 in.; 2RU); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.)
- Weight
- (Fully Populated): 22.7 kg (50 lb.)
- WARRANTY :For warranty Terms and Conditions, see the Warranty Website at: http://www.sun.com/service/warranty/product_warranty_chart.html
|
 |
|